Performance evaluation of serological assays to determine the immunoglobulin status in SARS-CoV-2 infected patients
Detection Principle
ImmunoAssay-Antibody
Target
IgA, IgM and IgG targeting S spike
Testing Method Category
ELISA
Testing Method
in-house
Testing Method - Additional Info
we have evaluated an in-house developed ELISA for the detection of the immunoglobulin classes A, G and M directed against the full-length spike glycoprotein from SARS-CoV-2
Reported Performance
Sensitivity values: of 98, 94, 98, 100 and 100 %, respectively. Specificity values: 78, 100, 83, 97 and 93 %
Sample Size
110 sera
Peer-reviewed
yes