Skip to main content
COVID-19 In Vitro Diagnostic Devices and Test Methods Database

Scientific literature on COVID-19 Test Methods and Devices - detail

Rapid quantification of SARS-CoV-2-neutralizing antibodies using propagation-defective vesicular stomatitis virus pseudotypes

Detection Principle
ImmunoAssay-Antibody
Target
neutralizing antibodies
Testing Method Category
 
Testing Method
in house (psudotyped virus) and kits (Allplex SARS-CoV-2 specific RT-qPCR assay, Seegene; RealStar SARS-CoV-2 RT-PCR Kit, Altona Diagnostic Technologies; Euroimmun AG, Lübeck, Germany # EI 2606-9601 G and # EI 2606-9601 A)
Testing Method - Additional Info
The pseudotype virus neutralization dose 50% (PVND50) and the SARS-CoV-2 neutralizing dose 50% (ND50) determined in the sera from two independent cohorts of individuals that had been tested positive for SARS-CoV-2 infection by RT-PCR and/or ELISA show good coorelation
Sample Size
29 samples
Peer-reviewed
yes

The database contains available information from scientific literature that is being updated periodically. Please note that the provided information (as retrieved from analysed papers) is provided only for devices commercially available with CE-IVD mark. Acknowledgements