Head-to-head comparison of four antigen-based rapid detection tests for the diagnosis of SARS-CoV-2 in respiratory samples
Detection Principle
ImmunoAssay-Antigen
Target
Not specified
Testing Method Category
Testing Method
kits
Testing Method - Additional Info
Immunochromatographic SARS-CoV-2 assays from RapiGEN, Liming bio, Savant, and Bioeasy compared to RT-PCR
Reported Performance
Ssensitivity: 62.0% (RapiGEN), 84.9% (RapiGEN, samples with high viral load), 16.7% (Liming bio), 85.0% (Bioeasy), 100% (Bioeasy, samples with high viral load); specificity: 100% (all).
Sample Size
111 samples
Peer-reviewed
no
The database contains available information from scientific literature that is being updated periodically. Please note that the provided information (as retrieved from analysed papers) is provided only for devices commercially available with CE-IVD mark. Acknowledgements