Skip to main content
COVID-19 In Vitro Diagnostic Devices and Test Methods Database

Scientific literature on COVID-19 Test Methods and Devices - detail

Evaluation of commercially available immuno-magnetic agglutination and enzyme-linked immunosorbent assays for rapid point-of-care diagnostics of COVID-19

Detection Principle
ImmunoAssay-Antibody
Target
IgM/IgA or IgG (IMA); IgA/IgG (ELISA)
Testing Method Category
 
Testing Method
microfluidic quantitative immunomagnetic assay (IMA) and ELISA kit
Testing Method - Additional Info
microfluidic quantitative immunomagnetic assay (IMA)(ViroTrack Sero COVID IgM+IgA/IgG Ab, Blusense Diagnostics, Denmark) ; enzyme-linked immunosorbent assay ((ELISA) (EuroImmun Medizinische Labordiagnostika, Germany).
Reported Performance
Sensitivity: 68% (IgA+IgM by IMA), 73% (IgG by IMA), 73% (IgG by ELISA), 90% (Ima and Elisa, >14 dpo); Specificity: 100% (IMA), 95% (ELISA IgA), 97.5% (ELISA IgG)
Sample Size
35 plasma from 22 patients & 40 controls
Peer-reviewed
no