Detection of serum IgM and IgG for COVID-19 diagnosis

Detection Principle
ImmunoAssay-Antibody
Target
IgM/IgG on N-protein, S-protein
Testing Method Category
 
Testing Method
ELISA in-house-method, CLIA in-house-method
Reported Performance
Sensitivity: 97.9% (rN IgG) ; 97.9% (rN IgM), 95.7% (rS IgG), 89.1% (rS IgM), 95.6% (CHEMIL IgG), 97.7% (CHEMIL IgM) ; Specificity: 99.7% (rN IgM), spec 99.7% (rN IgG), 85.7% (rS IgG), 99.0% (rS IgM), 96.6% (CHEMIL IgG), 95.2% (CHEMIL IgM)
Sample Size
47 patients & 300 controls
Peer-reviewed
yes