Combination of CT and RT-PCR in the screening or diagnosis of COVID-19

Detection Principle
mixed
Target
 
Testing Method Category
In_silico
Testing Method
CT imaging and RT-PCR in parallel or in series
Testing Method - Additional Info
We recommend that parallel tests are used in screening, while series tests should be used for diagnosis confirmation of COVID-19. Parallel tests perform RT-PCR and CT imaging at the same time and the results are cross-referenced to make the diagnosis. Serial test employs as a secondary screening test which is performed only if the result of initial screening test is positive.
Reported Performance
Sensitivity of chest CT imaging: 97%; specificity: 25%, with RT-PCR as a diagnosis criterion. Sensitivity of RT-PCR testing: 65%; specificity 83%, if chest CT as a reference of diagnosis standard. Remark: If both sensitivity and specificity were taken into account simultaneously, neither chest CT nor RT-PCR testing alone is accurate enough for the diagnosis of COVID-19 infection.
Sample Size
1014 patients