SARS-CoV-2 Antigen Rapid Test Kit

Manufactured by Wuhan UNscience Biotechnology Co. Ltd., China - www.uni-science.com 

Device identification number
2090
CE Marking
Yes
HSC common list (RAT)
Yes
Format
Lab-based, Manual
Physical Support
Cassette, Lateral flow
Target type
Antigen
Targets
nucleocapsid protein
Specimen
Mid-turbinates swab, Nasal swab, Nasopharyngeal swab, Oropharyngeal swab
Cross-reactivity (pathogens tested)
Adenovirus, Adenovirus 3, Adenovirus 7, Adenovirus Subtype B, Adenovirus Subtype C, Alpha Coronavirus 229E (HCoV-229E), Alpha Coronavirus Nl63 (HCoV-Nl63), Anti-Nuclear Antibody, Beta Coronavirus HKU1 (HCoV-HKU1), Beta Coronavirus OC43 (HCoV-OC43), Bordetella Pertussis, Chlamydia Pneumoniae, Coronaviruses (HCoV), Cytomegalovirus (CMV), Epstein-Barr Virus (EBV), Hemophilus Influenzae, Hepatitis A Virus (HAV), Hepatitis B Virus (HBV), Hepatitis C Virus (HCV), Herpes Simplex (HSV), Human Immunodeficiency Virus (HIV), Human Metapneumovirus (HMPV), Influenza A, Influenza A H1N1, Influenza A H3N2, Influenza A H5N1, Influenza B, Influenza B Victoria, Influenza B Yamagata, MERS-CoV, Mumps Virus (MuV), Mycobacterium Tuberculosis, Parainfluenza Virus Type 1, Parainfluenza Virus Type 2, Parainfluenza Virus Type 3, Parainfluenza Virus Type 4, Respiratory Syncytial V (RSV), Respiratory Syncytial V (RSV) Type A, Respiratory Syncytial V (RSV) Type B, Rhinovirus, Rhinovirus A, Rhinovirus B, SARS-CoV, Varicella Zoster Virus (VZV)
Lineages detected
A.23.1, B.1.1.7 (Alpha), B.1.351 (Beta), B.1.526 (Iota), B.1.526.1, B.1.526.2, B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.617.3, P.1 (Gamma), P.2 (Zeta)
Commercial Status
Commercialised
Last Update
2022-08-24 09:08:01 CET
Assay Type
Immuno-Antigen
Rapid Diagnostic
Yes
Reader Required
No
Subcategory
Other ()
Method
Immunochromatography
Measurement
Qualitative
Time
10 minutes
Subclass
Sandwich
LOD
50000 AU
Calibration
Evaluated
Analysis of cross reactivity
Evaluated
False positives
0.43 %
False negatives
3.67 %
Precision
Evaluated
Accuracy
100 % ( (Antigen))
Reproducibility
Evaluated
Robustness
Evaluated
Clinical Sensitivity
96.33 % ( (Antigen))
Clinical Specificity
99.57 % ( (Antigen))
Type of antigen
Nucleoprotein