Diagnostic performance between CT and initial real-time RT-PCR for clinically suspected 2019 coronavirus disease (COVID-19) patients outside Wuhan, China
Detection Principle
Others
Target
lung
Testing Method Category
Testing Method
CT scan
Testing Method - Additional Info
compare the performance of CT and initial RT-PCR for clinically suspected COVID-19 patients
Reported Performance
sensitivity: 79% (RT-PCR), 77% (Chest CT); specificity: 100% (RT-PCR), 96% (chest CT)
Sample Size
82(34 positive)
Peer-reviewed
yes
The database contains available information from scientific literature that is being updated periodically. Please note that the provided information (as retrieved from analysed papers) is provided only for devices commercially available with CE-IVD mark. Acknowledgements