<?xml version="1.0"?>
<data><element_extracted_on>2026-06-10 08:41:29 CET</element_extracted_on><deviceList><device_0><element_id_device>1454</element_id_device><element_commercial_name>COVID-19/Flu A/B Antigen Combo Rapid Test</element_commercial_name><manufacturer><element_id_manufacturer>340</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>www.gensbio.com/</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>No</element_hsc_common_list><element_hsc_mutual_recognition>No</element_hsc_mutual_recognition><element_physical_support/><format><element_0>Near POC / POC</element_0></format><target_type><element_0>Antigen</element_0></target_type><specimen><element_0>Nasal swab</element_0></specimen><pathogen/><lineage/><target><element_0>nucleocapsid protein</element_0></target><element_last_updated>2022-08-24 09:08:01 CET</element_last_updated><testList><device_0><element_id_test>1204</element_id_test><element_assay_category>Immuno-Antigen</element_assay_category><element_rapid_diagnostic>Yes</element_rapid_diagnostic><element_self_test/><element_reader_required>No</element_reader_required><element_method>Immunoassay</element_method><element_measurement>Qualitative</element_measurement><element_subclass/><element_detection_principle/><element_subcategory/><element_time_minutes>15</element_time_minutes><element_notes>Accuracy: 97.5 (Influenza A); 96.9 (Influenza B). Clinical sensitivity: 91.7 (Influenza A); 86.2 (Influenza B)</element_notes><performances><device_0><element_parameter>LOD</element_parameter><element_value>50</element_value><element_unit>AU</element_unit></device_0><device_1><element_parameter>Calibration</element_parameter><element_info>Not evaluated</element_info></device_1><device_2><element_parameter>Analysis of cross reactivity</element_parameter><element_info>Evaluated</element_info></device_2><device_3><element_parameter>False positives</element_parameter><element_info>The samples collected were contaminated, do not follow the instructions manual, etc. </element_info></device_3><device_4><element_parameter>False negatives</element_parameter><element_info>Samples collected contained low levels of the virus, do not follow the instructions manual, etc. </element_info></device_4><device_5><element_parameter>Precision</element_parameter><element_info>Evaluated</element_info></device_5><device_6><element_parameter>Accuracy</element_parameter><element_value>98.9</element_value><element_unit>%</element_unit><element_info>(COVID-19)</element_info></device_6><device_7><element_parameter>Reproducibility</element_parameter><element_info>Not evaluated</element_info></device_7><device_8><element_parameter>Robustness</element_parameter><element_info>Not evaluated</element_info></device_8><device_9><element_parameter>Clinical Sensitivity</element_parameter><element_value>96.9</element_value><element_unit>%</element_unit><element_info>(COVID-19)</element_info></device_9><device_10><element_parameter>Type of antigen</element_parameter><element_info>nucleoprotein</element_info></device_10></performances></device_0></testList></device_0><device_1><element_id_device>1253</element_id_device><element_commercial_name>GenSure COVID-19 Antigen Rapid Kit</element_commercial_name><manufacturer><element_id_manufacturer>340</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>www.gensbio.com/</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>Yes</element_hsc_common_list><element_hsc_mutual_recognition>Yes</element_hsc_mutual_recognition><element_physical_support/><format><element_0>Near POC / POC</element_0></format><target_type><element_0>Antigen</element_0></target_type><specimen><element_0>Nasal swab</element_0><element_1>Nasopharyngeal swab</element_1></specimen><pathogen><element_0>SARS-CoV-2</element_0></pathogen><lineage><device_0><element_id_lineage>678</element_id_lineage><element_lineage_name>B.1.1.529</element_lineage_name><element_lineage_country>Omicron</element_lineage_country></device_0><device_1><element_id_lineage>689</element_id_lineage><element_lineage_name>B.1.1.7</element_lineage_name><element_lineage_country>Alpha</element_lineage_country></device_1><device_2><element_id_lineage>1032</element_id_lineage><element_lineage_name>B.1.351</element_lineage_name><element_lineage_country>Beta</element_lineage_country></device_2><device_3><element_id_lineage>1132</element_id_lineage><element_lineage_name>B.1.427</element_lineage_name><element_lineage_country>Epsilon</element_lineage_country></device_3><device_4><element_id_lineage>1223</element_id_lineage><element_lineage_name>B.1.525</element_lineage_name><element_lineage_country>Eta</element_lineage_country></device_4><device_5><element_id_lineage>1224</element_id_lineage><element_lineage_name>B.1.526</element_lineage_name><element_lineage_country>Iota</element_lineage_country></device_5><device_6><element_id_lineage>1320</element_id_lineage><element_lineage_name>B.1.617.1</element_lineage_name><element_lineage_country>Kappa</element_lineage_country></device_6><device_7><element_id_lineage>1321</element_id_lineage><element_lineage_name>B.1.617.2</element_lineage_name><element_lineage_country>Delta</element_lineage_country></device_7><device_8><element_id_lineage>1323</element_id_lineage><element_lineage_name>B.1.621</element_lineage_name><element_lineage_country>Mu</element_lineage_country></device_8><device_9><element_id_lineage>2041</element_id_lineage><element_lineage_name>C.37</element_lineage_name><element_lineage_country>Lambda</element_lineage_country></device_9><device_10><element_id_lineage>1495</element_id_lineage><element_lineage_name>P.1</element_lineage_name><element_lineage_country>Gamma</element_lineage_country></device_10></lineage><target><element_0>nucleocapsid protein</element_0></target><element_notes>GenSure COVID-19 Antigen Rapid Test Kit (REF: P2004)</element_notes><element_last_updated>2022-11-28 10:30:56 CET</element_last_updated><testList><device_0><element_id_test>5343</element_id_test><element_assay_category>Immuno-Antigen</element_assay_category><element_rapid_diagnostic>Yes</element_rapid_diagnostic><element_self_test>No</element_self_test><element_reader_required>No</element_reader_required><element_method>Immunochromatography</element_method><element_measurement>Qualitative</element_measurement><element_subclass>Sandwich</element_subclass><element_detection_principle>Not found</element_detection_principle><element_subcategory/><element_time_minutes>15</element_time_minutes><performances><device_0><element_parameter>LOD</element_parameter><element_value>50</element_value><element_unit>TCID50/ml</element_unit></device_0><device_1><element_parameter>Calibration</element_parameter><element_info>Not evaluated</element_info></device_1><device_2><element_parameter>Analytical Sensitivity</element_parameter><element_value>96.86</element_value><element_unit>%</element_unit></device_2><device_3><element_parameter>Analytical Specificity</element_parameter><element_value>100</element_value><element_unit>%</element_unit></device_3><device_4><element_parameter>Analysis of cross reactivity</element_parameter><element_info>Evaluated</element_info></device_4><device_5><element_parameter>False positives</element_parameter><element_unit>%</element_unit></device_5><device_6><element_parameter>False negatives</element_parameter><element_value>3.14</element_value><element_unit>%</element_unit></device_6><device_7><element_parameter>Precision</element_parameter><element_info>Evaluated</element_info></device_7><device_8><element_parameter>Accuracy</element_parameter><element_value>98.91</element_value><element_unit>%</element_unit></device_8><device_9><element_parameter>Reproducibility</element_parameter><element_info>Evaluated</element_info></device_9><device_10><element_parameter>Robustness</element_parameter><element_info>Evaluated</element_info></device_10><device_11><element_parameter>Type of antigen</element_parameter><element_info>Nucleocapsid protein</element_info></device_11></performances></device_0></testList></device_1><device_2><element_id_device>2853</element_id_device><element_commercial_name>GenSure COVID-19 Antigen Rapid Test Kit</element_commercial_name><manufacturer><element_id_manufacturer>340</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>www.gensbio.com/</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>Yes</element_hsc_common_list><element_hsc_mutual_recognition>Yes</element_hsc_mutual_recognition><element_physical_support/><format><element_0>Manual</element_0></format><target_type><element_0>Antigen</element_0></target_type><specimen><element_0>Nasal swab</element_0><element_1>Saliva</element_1></specimen><pathogen/><lineage><device_0><element_id_lineage>689</element_id_lineage><element_lineage_name>B.1.1.7</element_lineage_name><element_lineage_country>Alpha</element_lineage_country></device_0><device_1><element_id_lineage>1032</element_id_lineage><element_lineage_name>B.1.351</element_lineage_name><element_lineage_country>Beta</element_lineage_country></device_1><device_2><element_id_lineage>1495</element_id_lineage><element_lineage_name>P.1</element_lineage_name><element_lineage_country>Gamma</element_lineage_country></device_2><device_3><element_id_lineage>1223</element_id_lineage><element_lineage_name>B.1.525</element_lineage_name><element_lineage_country>Eta</element_lineage_country></device_3><device_4><element_id_lineage>1137</element_id_lineage><element_lineage_name>B.1.429</element_lineage_name><element_lineage_country>Epsilon</element_lineage_country></device_4><device_5><element_id_lineage>1320</element_id_lineage><element_lineage_name>B.1.617.1</element_lineage_name><element_lineage_country>Kappa</element_lineage_country></device_5><device_6><element_id_lineage>1321</element_id_lineage><element_lineage_name>B.1.617.2</element_lineage_name><element_lineage_country>Delta</element_lineage_country></device_6><device_7><element_id_lineage>1322</element_id_lineage><element_lineage_name>B.1.617.3</element_lineage_name><element_lineage_country/></device_7><device_8><element_id_lineage>1323</element_id_lineage><element_lineage_name>B.1.621</element_lineage_name><element_lineage_country>Mu</element_lineage_country></device_8><device_9><element_id_lineage>2041</element_id_lineage><element_lineage_name>C.37</element_lineage_name><element_lineage_country>Lambda</element_lineage_country></device_9></lineage><target/><element_last_updated>2022-08-24 09:08:01 CET</element_last_updated><testList><device_0><element_id_test>2558</element_id_test><element_assay_category>Immuno-Antigen</element_assay_category><element_rapid_diagnostic>Yes</element_rapid_diagnostic><element_self_test/><element_reader_required>No</element_reader_required><element_method>Immunoassay</element_method><element_measurement>Qualitative</element_measurement><element_subclass/><element_detection_principle/><element_subcategory/><element_time_minutes>15</element_time_minutes><performances><device_0><element_parameter>LOD</element_parameter><element_value>50</element_value><element_unit>TCID50/ml</element_unit></device_0><device_1><element_parameter>Calibration</element_parameter><element_info>Not evaluated</element_info></device_1><device_2><element_parameter>Analysis of cross reactivity</element_parameter><element_info>Evaluated</element_info></device_2><device_3><element_parameter>False positives</element_parameter><element_info>There is a very small possibility of false positives.</element_info></device_3><device_4><element_parameter>False negatives</element_parameter><element_info>There is a very small possibility of false negatives.</element_info></device_4><device_5><element_parameter>Precision</element_parameter><element_info>Evaluated</element_info></device_5><device_6><element_parameter>Accuracy</element_parameter><element_value>98.68</element_value><element_unit>%</element_unit></device_6><device_7><element_parameter>Reproducibility</element_parameter><element_info>Evaluated</element_info></device_7><device_8><element_parameter>Robustness</element_parameter><element_info>Evaluated</element_info></device_8><device_9><element_parameter>Clinical Sensitivity</element_parameter><element_value>96.73</element_value><element_unit>%</element_unit></device_9><device_10><element_parameter>Clinical Specificity</element_parameter><element_value>100</element_value><element_unit>%</element_unit></device_10><device_11><element_parameter>Type of antigen</element_parameter><element_info>Nucleocapsid protein</element_info></device_11></performances></device_0></testList></device_2><device_3><element_id_device>565</element_id_device><element_commercial_name>GenSure COVID-19 IgG/IgM Rapid Test (REF: P2002)</element_commercial_name><manufacturer><element_id_manufacturer>340</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>www.gensbio.com/</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>No</element_hsc_common_list><element_hsc_mutual_recognition>No</element_hsc_mutual_recognition><element_physical_support/><format><element_0>Near POC / POC</element_0></format><target_type><element_0>Antibody</element_0><element_1>IgG</element_1><element_2>IgM</element_2></target_type><specimen><element_0>Whole blood</element_0></specimen><pathogen/><lineage/><target/><element_last_updated>2022-08-24 09:08:01 CET</element_last_updated><testList><device_0><element_id_test>450</element_id_test><element_assay_category>Immuno-Antibody</element_assay_category><element_rapid_diagnostic>Yes</element_rapid_diagnostic><element_self_test/><element_reader_required>No</element_reader_required><element_method>Immunoassay</element_method><element_measurement>Qualitative</element_measurement><element_subclass/><element_detection_principle/><element_subcategory/><element_time_minutes>15</element_time_minutes><performances/></device_0></testList></device_3><device_4><element_id_device>566</element_id_device><element_commercial_name>GenSure COVID-19 IgM Rapid Test (REF: P2001)</element_commercial_name><manufacturer><element_id_manufacturer>340</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>www.gensbio.com/</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>No</element_hsc_common_list><element_hsc_mutual_recognition>No</element_hsc_mutual_recognition><element_physical_support/><format><element_0>Near POC / POC</element_0></format><target_type><element_0>Antibody</element_0><element_1>IgM</element_1></target_type><specimen><element_0>Whole blood</element_0></specimen><pathogen/><lineage/><target/><element_last_updated>2022-08-24 09:08:01 CET</element_last_updated><testList><device_0><element_id_test>452</element_id_test><element_assay_category>Immuno-Antibody</element_assay_category><element_rapid_diagnostic>Yes</element_rapid_diagnostic><element_self_test/><element_reader_required>No</element_reader_required><element_method>Immunoassay</element_method><element_measurement>Qualitative</element_measurement><element_subclass/><element_detection_principle/><element_subcategory/><element_time_minutes>15</element_time_minutes><performances><device_0><element_parameter>Clinical Sensitivity</element_parameter><element_value>95</element_value><element_unit>%</element_unit></device_0><device_1><element_parameter>Clinical Specificity</element_parameter><element_value>95</element_value><element_unit>%</element_unit></device_1></performances></device_0></testList></device_4><device_5><element_id_device>1826</element_id_device><element_commercial_name>GenSure COVID-19 Neutralizing Antibody Test (Fluorescence)</element_commercial_name><manufacturer><element_id_manufacturer>340</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>www.gensbio.com/</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>No</element_hsc_common_list><element_hsc_mutual_recognition>No</element_hsc_mutual_recognition><element_physical_support/><format><element_0>Manual</element_0></format><target_type><element_0>Antibody</element_0></target_type><element_specimen/><pathogen/><lineage/><target/><element_last_updated>2022-08-24 09:08:01 CET</element_last_updated><testList><device_0><element_id_test>1503</element_id_test><element_assay_category>Immuno-Antibody</element_assay_category><element_rapid_diagnostic/><element_self_test/><element_reader_required/><element_method>Immunoassay</element_method><element_measurement/><element_subclass>Neutralization Antibody (NAb)</element_subclass><element_detection_principle/><element_subcategory/><element_time_minutes>15</element_time_minutes><performances><device_0><element_parameter>LOD</element_parameter><element_info>Evaluated</element_info></device_0><device_1><element_parameter>Calibration</element_parameter><element_info>Not evaluated</element_info></device_1><device_2><element_parameter>Analysis of cross reactivity</element_parameter><element_info>Evaluated</element_info></device_2><device_3><element_parameter>Precision</element_parameter><element_info>Evaluated</element_info></device_3><device_4><element_parameter>Reproducibility</element_parameter><element_info>Not evaluated</element_info></device_4><device_5><element_parameter>Robustness</element_parameter><element_info>Not evaluated</element_info></device_5></performances></device_0></testList></device_5><device_6><element_id_device>2112</element_id_device><element_commercial_name>GenSure COVID-19 Neutralizing Antibody Test (Latex)</element_commercial_name><manufacturer><element_id_manufacturer>979</element_id_manufacturer><element_name>GenSure Biotech Inc.</element_name><element_country>China</element_country><element_website>http://www.gensbio.com</element_website></manufacturer><element_ce_marking>Yes</element_ce_marking><element_commercial_status>Commercialised</element_commercial_status><element_hsc_common_list>No</element_hsc_common_list><element_hsc_mutual_recognition>No</element_hsc_mutual_recognition><element_physical_support/><element_format/><target_type><element_0>Antibody</element_0></target_type><element_specimen/><pathogen/><lineage><device_0><element_id_lineage>689</element_id_lineage><element_lineage_name>B.1.1.7</element_lineage_name><element_lineage_country>Alpha</element_lineage_country></device_0><device_1><element_id_lineage>1032</element_id_lineage><element_lineage_name>B.1.351</element_lineage_name><element_lineage_country>Beta</element_lineage_country></device_1></lineage><target/><element_last_updated>2022-08-24 09:08:01 CET</element_last_updated><testList><device_0><element_id_test>1802</element_id_test><element_assay_category>Immuno-Antibody</element_assay_category><element_rapid_diagnostic/><element_self_test/><element_reader_required/><element_method>Immunoassay</element_method><element_measurement/><element_subclass>Neutralization Antibody (NAb)</element_subclass><element_detection_principle/><element_subcategory/><element_time_minutes>15</element_time_minutes><performances><device_0><element_parameter>LOD</element_parameter><element_value>0</element_value><element_unit>AU</element_unit></device_0><device_1><element_parameter>Calibration</element_parameter><element_info>Not evaluated</element_info></device_1><device_2><element_parameter>Analysis of cross reactivity</element_parameter><element_info>Evaluated</element_info></device_2><device_3><element_parameter>False positives</element_parameter><element_info>There is a very small possibility of false positives.</element_info></device_3><device_4><element_parameter>False negatives</element_parameter><element_info>There is a very small possibility of false negatives.</element_info></device_4><device_5><element_parameter>Precision</element_parameter><element_info>Evaluated</element_info></device_5><device_6><element_parameter>Accuracy</element_parameter><element_value>98.1</element_value><element_unit>%</element_unit></device_6><device_7><element_parameter>Reproducibility</element_parameter><element_info>Not evaluated</element_info></device_7><device_8><element_parameter>Robustness</element_parameter><element_info>Not evaluated</element_info></device_8><device_9><element_parameter>Clinical Sensitivity</element_parameter><element_value>94.6</element_value><element_unit>%</element_unit></device_9><device_10><element_parameter>Clinical Specificity</element_parameter><element_value>100</element_value><element_unit>%</element_unit></device_10></performances></device_0></testList></device_6></deviceList></data>
